Upgrading SBR WWTP in Food Process

AMG ICEBT systems , ANOC units to Upgrading of SBR to meet tertiary treatment regulation

Using AMG ICEBT systems and ANOC units to intergrate with existing Physical -chemical biological treatment plant to upgrade treatment efficiency to comply with local regulations for reuse of treated industrial wastewater in industrial process or irrigation purpose .

our proposed designed solution provide the client with :-

1- 60 % reduction in CAPEX

2- 40 % reduction in OPEX

3- 95 % reduction in area required

4- 70 % reduction in electricity consumption

5- Class A treated water gurantee

SBR plant

AMG ICEBT systems , ANOC units to Upgrading of SBR to meet tertiary treatment regulation

Upgrading food processing plant to treat pollutants of high magnitude of triple its designed values

Our client existing system , current performance of treatment units and our proposed solution to bring its plant to tertiary treatment level without any needs for new big land to build more reactors and wastewater treatment units

Our client raw wastewater analysis is

  Parameters   Units   Inlet
  Ph.   —   6 – 6.56
  Chemical oxygen demand COD   mgO2/l   6325 – 11024
  Biological oxygen demand BOD   mgO2/l   3025 – 5115
  Total suspended solids TSS   mg/l   2530 – 6186
  Total nitrogen   mg/l   55 – 600
  Total phosphorous   mg/l   15 – 38.5
  Oil & grease   mg/l   280 – 456

The targeted effluent quality is

Parameters Units Ministerial Decree
Temperature °C 43
pH 6 — 9.5
COD mgO2/l 1100
BOD mgO2/l 600
TSS mg/l 800
TDS mg/l
TKN mg/l 100
Phenol mg/l 0.05
Total P mg/l 25
Soluble Hydrogen Sulfide mg/l 10
FOG mg/l 100
Settled solids 10 min ml /l 8
Settled solids 30min ml /l 15

Our designed effluent criteria are

Parameters Units Final
Ph.  7
Chemical oxygen demand COD mgO2/l 36
Biological oxygen demand BOD mgO2/l 23
Total suspended solids TSS mg/l 3
Total nitrogen mg/l 3
Total phosphorous mg/l 0.1
Oil & grease mg/l 1

Message Us on WhatsApp